Contact resistance
Resistance across the mated connector contact path, typically from a periodic four-wire (Kelvin) inspection measurement.
- Latest
- 0.207 mΩ
- Baseline median
- —
- Valid readings
- 4
- Typical interval
- 7 days
Temperature-corrected to 20 °C (readings taken at 24–27 °C). Values shown are corrected.
What this means
There are too few valid readings to judge this metric yet.
- All 4 readings were restated at 20 °C (recorded 23.5–27.3 °C, coefficient 0.39% per °C). The largest adjustment to one reading was 2.8%. Baselines, alerts and forecasts use the restated values.
- 4 valid observation(s); at least 9 are needed (6 for a baseline plus 3 to compare).
Data quality
- 4 valid observation(s); at least 9 are needed (6 for a baseline plus 3 to compare).