Which connectors will reach their service limit next, and when. Each date extends the connector's recent rate of change; the range is the uncertainty in that rate.
Soonest first. Open a charger to see the readings, the limit line and the full explanation.
| Charger | Metric | Likely date | Range | Now / limit |
|---|---|---|---|---|
| DEMO-01-C2Demo Site A — Guindy area Demo | Contact resistance | Now — already above | — | 0.492 mΩ / 0.472 mΩdefault limit |
| ST-01-V2GStation 1 · historical data | Charging-path power loss | Now — already above | — | 3.24 kW / 2.79 kWdefault limit |
| ST-02-FASTStation 2 · historical data | Charging-path power loss | Now — already above | — | 3.51 kW / 3.05 kWdefault limit |
| ST-02-V2GStation 2 · historical data | Charging-path power loss | Now — already above | — | 4.08 kW / 2.17 kWdefault limit |
| ST-03-CONVENTIONALStation 3 · historical data | Charging-path power loss | Now — already above | — | 3.27 kW / 3.06 kWdefault limit |
| ST-04-CONVENTIONALStation 4 · historical data | Charging-path power loss | Now — already above | — | 4.15 kW / 2.52 kWdefault limit |
| ST-06-V2GStation 6 · historical data | Charging-path power loss | Now — already above | — | 3.71 kW / 3.52 kWdefault limit |
| ST-09-FASTStation 9 · historical data | Charging-path power loss | Now — already above | — | 3.26 kW / 0.83 kWdefault limit |
| ST-10-CONVENTIONALStation 10 · historical data | Charging-path power loss | Now — already above | — | 4.28 kW / 2.66 kWdefault limit |
| ST-11-FASTStation 11 · historical data | Charging-path power loss | Now — already above | — | 4.12 kW / 3.6 kWdefault limit |
| ST-12-CONVENTIONALStation 12 · historical data | Charging-path power loss | Now — already above | — | 3.31 kW / 2.59 kWdefault limit |
| ST-13-CONVENTIONALStation 13 · historical data | Charging-path power loss | Now — already above | — | 4.35 kW / 3.96 kWdefault limit |
| ST-18-CONVENTIONALStation 18 · historical data | Charging-path power loss | Now — already above | — | 3.13 kW / 3.1 kWdefault limit |
| ST-17-V2GStation 17 · historical data | Charging-path power loss | 11 Jan 2024 | 11 Jan 2024 – 11 Jan 2024 (80%) | 3.59 kW / 3.62 kWdefault limit |
| ST-04-FASTStation 4 · historical data | Charging-path power loss | 12 Jan 2024 | 11 Jan 2024 – 17 Jan 2024 (80%) | 2.95 kW / 3.38 kWdefault limit |
| DEMO-03-C1Demo Site C — Adyar area Demo | Connector voltage drop | 07 Nov 2026 | 03 Nov 2026 – 12 Dec 2026 (80%) | 45.7 mV / 48.6 mVdefault limit |
| DEMO-13-C2Demo Site M — Kilpauk area Demo | Contact resistance | 18 Nov 2026 | 14 Nov 2026 – 24 Nov 2026 (80%) | 0.337 mΩ / 0.381 mΩdefault limit |
| DEMO-06-C1Demo Site F — OMR / Sholinganallur area Demo | Contact resistance | 20 Dec 2026 | 10 Dec 2026 – 25 Dec 2026 (80%) | 0.328 mΩ / 0.39 mΩdefault limit |
| DEMO-05-C2Demo Site E — Anna Nagar area Demo | Contact resistance | 06 Jan 2027 | 30 Dec 2026 – 16 Jan 2027 (80%) | 0.269 mΩ / 0.322 mΩdefault limit |
| DEMO-06-C1Demo Site F — OMR / Sholinganallur area Demo | Connector voltage drop | 21 Feb 2027 | 04 Feb 2027 – 18 Mar 2027 (80%) | 39.2 mV / 50.6 mVdefault limit |
| DEMO-09-C1Demo Site I — Katpadi area Demo | Contact resistance | After 15 Oct 2027 | 15 Oct 2027 – later (80%) | 0.31 mΩ / 0.438 mΩdefault limit |
Method: Theil–Sen rate over the latest 12 readings since the most recent recorded maintenance; Sen's 80% interval sets the range; no date unless the whole interval is above zero. Default limit = baseline median + 50%, replaceable per charger.