Contact resistance
Resistance across the mated connector contact path, typically from a periodic four-wire (Kelvin) inspection measurement.
- Latest
- 0.359 mΩ
- Baseline median
- 0.254 mΩ
- Valid readings
- 26
- Typical interval
- 7 days
Baseline from the first 12 readings (02 May 2026 to 18 Jul 2026).
Temperature-corrected to 20 °C (readings taken at 25–39 °C). Values shown are corrected.
Service forecast
Service limit likely around 18 Nov 2026
80% range: 14 Nov 2026 – 24 Nov 2026
At the recent rate (about 0.052 mΩ per 30 days, from 10 readings over 63 days since the maintenance on 18 Aug 2026), the level would reach the default service limit of 0.381 mΩ (baseline + 50%; set your own on this charger) around 18 Nov 2026 (80% range: 14 Nov 2026 to 24 Nov 2026).
Limit 0.381 mΩ (default: baseline + 50%). A forecast extends the recent rate; maintenance, load or weather can change it.