Contact resistance
Resistance across the mated connector contact path, typically from a periodic four-wire (Kelvin) inspection measurement.
- Latest
- 0.269 mΩ
- Baseline median
- 0.215 mΩ
- Valid readings
- 26
- Typical interval
- 7 days
Baseline from the first 12 readings (02 May 2026 to 18 Jul 2026).
Temperature-corrected to 20 °C (readings taken at 26–37 °C). Values shown are corrected.
Service forecast
Service limit likely around 06 Jan 2027
80% range: 30 Dec 2026 – 16 Jan 2027
At the recent rate (about 0.021 mΩ per 30 days, from 12 readings over 77 days), the level would reach the default service limit of 0.322 mΩ (baseline + 50%; set your own on this charger) around 06 Jan 2027 (80% range: 30 Dec 2026 to 16 Jan 2027).
Limit 0.322 mΩ (default: baseline + 50%). A forecast extends the recent rate; maintenance, load or weather can change it.