Contact resistance
Resistance across the mated connector contact path, typically from a periodic four-wire (Kelvin) inspection measurement.
- Latest
- 0.51 mΩ
- Baseline median
- 0.314 mΩ
- Valid readings
- 26
- Typical interval
- 7 days
Baseline from the first 12 readings (02 May 2026 to 18 Jul 2026).
Temperature-corrected to 20 °C (readings taken at 26–38 °C). Values shown are corrected.
Service forecast
Already at or above the service limit
The current level, 0.492 mΩ (median of the last three readings), is already at or above the default service limit of 0.472 mΩ (baseline + 50%; set your own on this charger).
Limit 0.472 mΩ (default: baseline + 50%). A forecast extends the recent rate; maintenance, load or weather can change it.