Contact resistance
Resistance across the mated connector contact path, typically from a periodic four-wire (Kelvin) inspection measurement.
- Latest
- 0.205 mΩ
- Baseline median
- 0.212 mΩ
- Valid readings
- 26
- Typical interval
- 7 days
Baseline from the first 12 readings (02 May 2026 to 18 Jul 2026).
Temperature-corrected to 20 °C (readings taken at 24–38 °C). Values shown are corrected.
Service forecast
No clear rise — no service date forecast
Over the last 8 readings (49 days) there is no statistically clear rise (80% range of the rate: -0.0128 to 0.0018 mΩ per 30 days), so no date is forecast.
Limit 0.318 mΩ (default: baseline + 50%). A forecast extends the recent rate; maintenance, load or weather can change it.
What this means